2 contingency tables. Five eligible studies were found, all in the acute setting (although one paper collected its data in the follow-up setting, all patients had acute presentations). The sensitivity ranged from 35% to 92% and the specificity from 12% to 63%. However, in all but one paper the Youden indices were close to zero suggesting that the response to nitroglycerine is not useful as a diagnostic test. The combined sensitivity was 0.52 (95% CI 0.48 to 0.56) and combined specificity was 0.49 (95% CI 0.46 to 0.52). The diagnostic OR from the combined studies was 1.2 (95% CI 0.97 to 1.5), which is not significantly different from 1. In the acute setting, nitroglycerine is not a reliable test of treatment for use in the diagnosis of coronary artery disease. However, further studies are needed to determine the diagnostic accuracy of nitroglycerine for recurrent exertional chest pain. Cardiac care acute coronary syndrome thrombo-embolic disease diagnosis Footnotes Competing interests None. Provenance and peer review Not commissioned; externally peer reviewed.
View the Original article